Menşe yeri:
ÇİN
Marka adı:
E+H
Model numarası:
03031
What is the Rosemount 03031 LCD Display (LCD Meter)?
Key Features & Capabilities
From Rosemount’s documentation:
Feature |
Description |
Display format |
Two lines: first line shows up to five digits for the process variable; second line shows engineering units (up to six characters) |
Display modes |
Can display: engineering units, percent of range, user-configurable scale, or alternate between two modes |
User-configurable scale |
You can set a custom scale (lower/upper limits, decimal point, units, transfer function) for display independent of the transmitter’s analog output behavior |
Diagnostics |
Displays abbreviated diagnostic or alarm messages (e.g. error codes) on both lines as needed |
Compatibility |
Works with Rosemount transmitters that support the LCD meter, such as the Model 3051, 2051, etc. |
Power / interface |
The LCD meter receives data from the transmitter’s electronics board (via a 10-pin interconnection header) and shows the output directly. |
Temperature / environmental limits |
Operating temperature: –20 °C to +80 °C (–4 °F to 175 °F) |
Installation constraints |
Requires an extended cover in the transmitter housing to physically accommodate the LCD module. Also, the display and electronics are electrostatic discharge (ESD) sensitive; care must be taken during handling. |